Pump Calibration Solution for Titratable Acidity in Water Titrator - HI84430-55M

The HI84430 incorporates a peristaltic pump dosing system for the accurate delivery of a titrant. The HI84430 can titrate both high and low ranges of total acidity in water using two different titrant solutions. If the range is changed, the titrant must be changed and the pump must be purged and recalibrated. Pump calibrations are performed with the provided HI84430-55M pump calibration solution, helping to assure the accuracy of the measurement. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.

  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal to ensure quality

Description

The HI84430-55M is a 230 mL bottle of pump calibration solution that is used for both low and high range determination of acidity in water.

The determination of water acidity is based on the neutralization of all acidic species contained in water samples by titration with a basic titrant solution:

H+ + OH → H2O

The endpoint of an acid base titration corresponds stoichiometrically to the complete neutralization of the acids present. Water acidity results from strong and weak acids as well as from the hydrolysis of salts. Due to these more complex mixtures, endpoints for water acidity are arbitrarily fixed on practical considerations. Unpolluted surface waters contain carbon dioxide as the main acidic component, and titration of these samples corresponds to the stoichiometric neutralization of carbonic acid with sodium hydroxide. The titration to pH 8.3 represents total acidity. The titration to pH 3.7 represents strong acidity from polluted water. If the samples are suspected to contain hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese), it is necessary to pretreat the samples with HI84430-58 reagent.

Titratable acidity in waters, as performed on the HI84430 mini titrator, utilizes a simple sample preparation, a high quality titrant dosing pump, potentiometric endpoint detector, and automatic computations. To maintain the high precision of the titrator, a simple pump calibration procedure is required. A change of measurement range requires a different titrant along with a pump recalibration. The pump calibration involves the analysis of a known volume of a known solution and compensates for changes in pump dosing that may occur due to many factors including tube stretching or aging. This procedure should be performed regularly with the HI84430-55M pump calibration solution to accurately determine acidity levels in water.

Replacement reagents required to operate the HI84430:

Low Range – 15 to 500 mg/L as CaCO3

High Range – 400 to 4000 mg/L as CaCO3

Pump calibration standard

HI84430-55M

HI84430-55M

Titrant solution

HI84430-50

HI84430-51

Additional reagent*

HI84430-58

HI84430-58

* Used with samples containing hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese)

Additional information

Weight 0.29 kg

Specifications

SKU HI84430-55M
Name Pump Calibration Solution for Titratable Acidity in Water Titrator – HI84430-55M
Description Pump Calibration Solution for Titratable Acidity in Water Titrator
Package bottle
Quantity 1
Size 230 mL

Manuals

Pump Calibration Solution for Titratable Acidity in Water Titrator – HI84430-55M