Hanna Instruments Taiwan
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +886-2-8797-2918
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

Total Phosphorus Low Range Reagents with Barcode Recognition - HI94758C-50

The HI94758C-50 are reagents that follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method for the determination of reactive phosphorus using the compatible HI83224 benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-dosed reagents for ease of use
  • Barcoded vials
  • Marked with expiration date and lot number for traceability

Description

The HI94758C-50 reagent kit contains 50 ready-to-use vials of HI94758V-0, 1 bottle of HI93758C-0 solution, 50 packets of potassium persulfate reagent, and 50 packets of HI93758-0 phosphorus reagent. These high quality reagents follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. In this method, a persulfate digestion converts organic and condensed inorganic forms of phosphates to orthophosphate then the reaction between orthophosphate and the reagent causes a blue tint in the sample. The amount of phosphorus is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the concentration is displayed in mg/L (ppm) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.15 mg/L (ppm) phosphorus.

Hanna vials contain pre-dosed reagent so the user simply needs to add a small quantity of the sample to the vial along with a packet of the potassium persulfate reagent followed by heating 30 minutes at 150℃ and cooling, then the addition of the NaOH solution to use as the blank, followed by the addition of the phosphorus powder reagent to measure the concentration. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized. These vials feature Hanna’s barcode recognition system exclusive to the HI83224 Wastewater Treatment benchtop photometer. The meter scans each vial to automatically identify sample method and range. The barcode has four digits: the first two digits are for parameter identification and the second two digits are for reagent lot ID. Vials for different methods can be distinguished by a barcode printed on the vial and the cap color.

Additional information

Weight 1.41 kg
Parameter

Phosphorus

Specifications

SKU HI94758C-50
Name Total Phosphorus Low Range Reagents with Barcode Recognition – HI94758C-50
Package Vials, bottle, and packets
Quantity 50 tests
Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method

Manuals

Total Phosphorus Low Range Reagents with Barcode Recognition – HI94758C-50