Pump Calibration Standard for Sulfur Dioxide Mini Titrator - HI84500-55

The HI84500-55 is a 120 mL bottle of pump calibration standard that is used to calibrate the dosing system of the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis.

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84500 in determining the exact concentration of sulfur dioxide. The pump calibration procedure should be performed anytime the titrant or ORP electrode is replaced.

  • Standardized solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

Description

Analysis of sulfur dioxide in wine, as performed on the HI84500 mini titrator, utilizes a simple sample preparation, a high quality titrant dosing pump, potentiometric endpoint detector, and automatic computations. To maintain the high precision of the titrator, a simple pump calibration procedure is performed with HI84500-55 pump calibration solution. The pump calibration procedure involves the analysis of a known volume of a known solution. The pump calibration procedure should be performed anytime the titrant, syringe, tubing or ORP electrode is replaced. Periodic calibrations should be performed in order to accurately determine the free and total sulfur dioxide levels in wine.

The HI84500 determines the free and total sulfur dioxide concentration in wine using the Ripper method. Excess iodide is added to the wine sample and reacts with the iodate titrant to produce iodine:

IO3 + 5I + 6H+ → 3I2 + 3H2O

The iodine produced reacts with sulfur dioxide in the wine according to the redox reaction below:

H2SO3 + I2 → H2SO4 + 2HI

Replacement reagents required to operate the HI84500 include:

Low Range – 1.0 to 40.0 ppm of SO2

High Range – 30 to 400 ppm of SO2

Pump calibration standard

HI84500-55

HI84500-55

Titrant solution

HI84500-50

HI84500-51

Acid reagent

HI84500-60

HI84500-60

Alkaline reagent (Total SO2)

HI84500-61

HI84500-61

Stabilizer powder packets

HI84500-62

HI84500-62

Additional information

Weight 0.15 kg
Parameter

Sulfur Dioxide

Specifications

SKU HI84500-55
Name Pump Calibration Standard for Sulfur Dioxide Mini Titrator – HI84500-55
Description Pump Calibration Standard for Sulfur Dioxide Mini Titrator
Package bottle
Quantity 1
Size 120 mL