Description
The HI9813-6 portable meter features a large LCD which displays either pH, EC, TDS or temperature readings along with tutorial instructions. The pH readings are displayed with a 0.1 resolution and an accuracy of ±0.1 pH while the EC and TDS readings are displayed with a 0.01 mS/cm and 1 ppm (mg/L) resolution and 2% full-scale accuracy. The EC range of the HI9813-6 is from 0.00 to 4.00 mS/cm and TDS is from 0 to 1999 ppm. The temperature correction coefficient (β) is fixed at 2 %/oC and allows for automatic temperature compensated measurements of EC and TDS. The HI9813-6 is a basic pH/EC/TDS meter that is calibrated manually to a single point with the use of two trimmers. pH is calibrated to pH 7.01 while EC/TDS is calibrated to either 1.41 mS/cm (1413 µS/cm) or 1500 ppm. The LCD screen has battery life indicator as well as on-screen tutorial messages. The supplied HI1285-6 probe is a polypropylene body, amplified pH electrode with a built-in EC/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and electrical noise from common sources including from motors, ballasts or pumps. The HI9813-6 is a versatile meter for the agriculture, greenhouse and hydroponics industries.
The HI9813-6 meter also offers the CAL Check™ feature that alerts the user to a problem with a pH electrode. This feature is important for customers that calibrate only to pH 7.0; if there is a fracture on the pH glass of the electrode, the pH meter will always display pH 7.0 regardless of the solution being measured. This can be disastrous for the person that calibrates at pH 7.0 and takes readings of samples with an expected pH of 7.0. The user will never be aware that there is a problem with the electrode. This can result in inaccurate pH measurements, which for a greenhouse can affect the growth of the plants. Placing the HI1285-6 pH/EC electrode in the HI50021 CAL Check™ solution helps users determine if the probe needs to be calibrated, cleaned or replaced. When the probe is placed in solution the user presses the “Check” key. The meter runs CAL Check™ diagnostics and will display either “Probe is OK” or “Clean Probe and Calibrate”. If the reading is around pH 4.0 when the probe is placed in the solution then the probe is broken and needs to be replaced.
HI1285-6 polypropylene body amplified pH electrode with built-in EC/TDS and temperature sensors
The HI9813-6 is supplied with a polypropylene body pH/EC/TDS/temperature probe. The pH, EC, TDS, and temperature sensor are housed in a single body that connects to the meter with a DIN connector.
Amplified pH electrode
The pH electrode circuit has a built-in amplifier that will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include motors, ballasts, and pumps which are common in greenhouses.
Amperometric EC/TDS sensor
The EC/TDS readings are performed by an amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins is dependent upon the amount of salts (fertilizer) present. A greater amount of salt present results in an increase in conductance.
Polypropylene body
The polypropylene body houses all the sensors in a single body design and is durable. The probe is gel filled for maintenance free operation. It does not have to be refilled periodically.
- 3 sensors in a single probe
- Pre-amplified pH electrode for resistance to electrical noise
- Gel filled maintenance free pH electrode
Features at-a-glance
Water Resistant
CAL Check™
Variable EC to TDS conversion factor
- Factor automatically adjusts from 0.56 to 0.78 based on actual EC readings
- Factor based on 442 curve for natural water
Automatic Temperature Compensation
- All readings are compensated for variations in temperature
Low Battery Indicator