Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter - HI98195-40m (131.2')

The HI98195 is a waterproof portable logging multiparameter meter that monitors up to 10 different water quality parameters including 5 measured and 5 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The complete system is simple to setup and easy to use. The HI98195 is supplied with all necessary accessories and packaged in a durable carrying case.

Multi-Parameter Display

Multi-Parameter Display

Multi-function sensor

Multi-sensor Probe

micro USB

USB Connection

Description

The HI98195 is a waterproof portable logging multiparameter meter that monitors up to 10 different water quality parameters including 5 measured and 5 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The complete system is simple to setup and easy to use. The HI98195 is supplied with all necessary accessories and packaged in a durable carrying case.

Multi-Parameter Display

Multi-Parameter Display

Multi-function sensor

Multi-sensor Probe

micro USB

USB Connection

Additional information

Weight 0.01 kg
Parameter

Conductivity/TDS, ORP, pH, Resistivity, Salinity, Temperature

pH Accuracy

±0.02 pH

pH Calibration

10.01) or one custom buffer, 6.86, 7.01, 9.18, automatic one, or three points with automatic recognition of five standard buffers (pH 4.01, two

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

111.8 mS/cm) or custom point, 12.88 mS/cm, 1413 µS/cm, 5.00 mS/cm, 80.0 mS/cm, automatic single point, with six standard solutions (84 µS/cm

EC Range

0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm)

EC Resolution
TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity calibration

TDS Range

0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor)

TDS Resolution
Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Specifications

SKU HI98195/40
Name Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter – HI98195-40m (131.2′)
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.5 mV
EC Range 0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm)
EC Resolution auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor)
TDS Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt):
TDS Accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration based on conductivity calibration
Salinity (PSU) Range 0.00 to 70.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity (PSU) Calibration based on conductivity calibration
Salinity (Seawater Sigma) Range 0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Resolution 0.1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Accuracy ±1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Calibration based on conductivity calibration
Resistivity Range 0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity calibration
Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration automatic at one custom point
Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F)
Logging Memory 45,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval one second to three hours
Connectivity USB to PC with HI9298194 Hanna software installed
Battery Type/Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)

Ordering Info

HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI 76981952 Probe maintenance kit (O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.

Manuals