Hanna Instruments Taiwan
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +886-2-8797-2918
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

Bromine Checker® HC - HI716

The Hanna Bromine Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Bromine Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.

  • Compact, Portable Design
  • Built-in Timer
  • One-Button Operation

Description

The HI716 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure bromine. Introduced as an alternative to chlorine, the use of bromine as a sanitizer is increasing in use in many countries. Bromine is less volatile and has more effective results above a pH of 7.4, but is an overall slower acting disinfectant. Designed as a more accurate alternative to chemical test kits, the HI716 provides quick, accurate results in four easy steps:

How to use Hanna Checker Handheld Colorimeter

Features at-a-glance:

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Water Quality, Industrial, Municipal Water, Pool and Spa

Additional information

Weight 0.32 kg
Parameter

Bromine

Specifications

SKU HI716
Name Bromine Checker® HC – HI716
Bromine Range 0.00 to 8.00 ppm
Bromine Resolution 0.01 ppm
Bromine Accuracy ±0.08 ppm ±5% of reading @ 25 ℃
Bromine Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.
Photometer/Colorimeter Light Source LED @ 525 nm
Photometer/Colorimeter Light Detector silicon photocell
Battery Type/Life (1) 1.5V AAA
Automatic Shut-Off after ten minutes of non-use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 64 g (2.25 oz.)
Dimensions 86.0mm x 61mm x 37.5mm (3.4 in. x 2.4 in. x 1.5”)