Free & Total Chlorine High Range Portable Photometer – HI97734

The HI97734 measures free and total chlorine in water samples from 0.00 to 10.00 mg/L (ppm) as Cl2. The combination of an advanced optical system for accurate measurements and user-friendly design makes the HI97734 the perfect photometer for your water quality testing needs.

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

Description

The HI97734 is designed to measure free chlorine in water up to 10.00 mg/L (ppm). In swimming pools, drinking water, and food processing chlorine is used to disinfect and keep bacteria from growing. Industrially, chlorine is used in metal finishing as an oxidizer to convert cyanide in wastewater to cyanate and used to bleach wood pulp in the pulp and paper industry.

Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive‑locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.

photometer optical system
  • LED that generates very little heat.
  • 8 nm narrowband interference filter that is accurate to ±1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output. 
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

On-Screen Features

CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.

Reaction Timer
Built-in reaction timer that ensures consistency amongst multiple users.

method option

Setup Options
Backlit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.

Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

HI97734 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97734 photometer compensates for any drift due to power fluctuations or ambient temperature changes. This stable light source gives faster, more stable readings of sample measurements.

High Efficiency Light Source:

  • LED light sources have higher luminous efficiency, provide more light with less power, and produce minimal heat interference that could impact electronic stability.

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

Large Cuvette Size:

  • The sample cell of the HI97734 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Dedicated Help Key:

  • A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.

Additional information

Weight 0.45 kg
Parameter

Chlorine

Specifications

SKU HI97734-web
Name Free & Total Chlorine High Range Portable Photometer – HI97734
Free Chlorine Range 0.00 to 10.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 10.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of US EPA method 330.5, DPD Colorimetric Method
Photometer/Colorimeter Light Source LED at 525 nm
Photometer/Colorimeter Light Detector Silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Cuvette Type Round 24.6 mm diameter (22 mm inside)
GLP Yes (Date, time of last calibration)
Display 128 x 64 pixel B/W LCD with backlight
Logging Type Automatic logging of last 50 measurement
Battery Type/Life 1.5V AA battery (3 pcs.), >800 measurements (without backlight)
Automatic Shut-Off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50°C (32 to 122°F); relative humidity: 100% (IP67)
Weight 380 g (13.4 oz.)
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0”)

Ordering Info

HI97734C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate. HI97734 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate.