The HI96716 portable photometer is for the measurement of bromine. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system

Features at-a-glance

*Reagents ordered separately

cal check standards

CAL Check™ standards with certificate

The HI96716-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25 ℃
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage
photometer steps

Additional information

Weight 0.08 kg
Parameter

Bromine

Specifications

SKU HI96716-web
Name Bromine Portable Photometer – HI96716
Bromine Range 0.00 to 10.00 mg/L (ppm)
Bromine Resolution 0.01 mg/L (ppm)
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method
Photometer/Colorimeter Light Source tungsten lamp
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 525 nm
Battery Type/Life 9V battery
Automatic Shut-Off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360g (12.7oz.)
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)